[Free] 2017(Nov) Dumps4cert Testinsides Cisco 300-180 Dumps with VCE and PDF Download 21-30

Dumps4cert 2017 Nov Cisco Official New Released 300-180
100% Free Download! 100% Pass Guaranteed!
http://www.Dumps4cert.com/300-180.html

Troubleshooting Cisco Data Center Infrastructure

Question No: 21 – (Topic 1)

You have an unresponsive blade server. You suspect that there is an issue with the current firmware. Which action do you take to reboot the server from the Cisco UCS Manager GUI?

  1. Reset the server.

  2. Reset CIMC.

  3. Reset BMC.

  4. Recover the corrupt BIOS.

Answer: B

Question No: 22 – (Topic 1)

A local storage installation of ESX on a Cisco UCS C-Series server has failed due to local storage issues. What is the cause of the problem?

  1. LSI drivers are not bundled with ESX.

  2. The hard drive has a 1-TB partition size.

  3. The server only has an onboard controller, while ESX requires an LSI RAID controller card.

  4. ESX is not supported on Cisco UCS C-series servers.

Answer: C

Question No: 23 – (Topic 1)

A customer is configuring a network control policy in a Cisco UCS domain. The network control policy configures the network control settings for the Cisco UCS domain, including which three of these? (Choose three.)

  1. how the VIF behaves if no uplink port is available in end-host mode

  2. the action that the Cisco UCS Manager takes on the remote Ethernet interface, vEthernet interface, or vFibreChannel interface when the associated border port fails

  3. Layer 2 switching on the fabric interconnect

  4. whether MAC registration occurs on a per-vNIC basis or for all VLANs

  5. the end-host mode setting on the I/O module

Answer: A,B,D

Question No: 24 – (Topic 1)

When a service profile is disassociated from a server, what happens to the identity and connectivity information for the server?

  1. It is cleared and set to the default that was setup initially by the first configuration.

  2. It is maintained and can be reused.

  3. It is reset to factory defaults.

  4. It uses master service profile parameters.

  5. It takes parameters of other servers in the service profile.

Answer: C

Question No: 25 – (Topic 1)

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

What is the reason that no C-Series servers can access Fibre Channel storage from this Cisco Nexus 554SUP switch?

  1. Zoning mode mis-match with the MDS 9124

  2. There are no active Fibre Channel interfaces

  3. VSAN mis-match on Fibre Channel interfaces

  4. None of the virtual fibre channel interfaces are configured

Answer: A

Question No: 26 – (Topic 1)

Which four tech support files can you create with the Cisco UCS Manager that you can submit to Cisco TAC for support? (Choose four.)

  1. UCSM

  2. disk LUNs

  3. fabric extender

  4. memory

  5. rack server

  6. chassis

  7. server cache

Answer: A,C,E,F

Question No: 27 – (Topic 1)

For a KVM session to be successful, which two of these need to be done? (Choose two.)

  1. The Cisco IMC IP address needs to be assigned on the Admin tab.

  2. The Cisco IMC IP address needs to be in the same subnet as the management IP.

  3. The Cisco IMC needs to be upgraded to the same version as the UCS Manager.

  4. The server needs to be fully discovered.

Answer: A,D

Question No: 28 – (Topic 1)

During a Cisco UCS firmware update via the UCS Manager GUI, you choose All from the Filter list in the Activate Firmware dialog box. Which statement about this action is true?

  1. Because many releases and patches have dependencies that require a specific order, this method is not preferred, and you should consult the release notes.

  2. This setting will work and UCS Manager will properly activate all elements in the correct order.

  3. This setting will have no effect, and you should always use the CLI to complete firmware upgrades.

  4. You should open a case with Cisco TAC to determine what to do.

Answer: A

Question No: 29 – (Topic 1)

Which command output shows the interface assigned as the designated receiver of each VLAN?

  1. show system vlan reserved

  2. show vlan internal bd-info bd-to-vlan all-bd

  3. show port internal info all

  4. show platform software enm internal info vlandb all

Answer: D

Question No: 30 – (Topic 1)

Which statement about Cisco UCS version compatibility is true?

  1. All bundles (A, B, and C) must be the same version.

  2. The B and C bundles must be the same revision.

  3. The A bundle can be one revision higher than the B/C bundles.

  4. The B/C bundles can be one revision higher than the A bundles.

Answer: C

100% Free Download!
Download Free Demo:300-180 Demo PDF
100% Pass Guaranteed!
Download 2017 Dumps4cert 300-180 Full Exam PDF and VCE

Dumps4cert ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 Dumps4cert IT Certification PDF and VCE