Troubleshooting Cisco Data Center Infrastructure

Question No: 161 – (Topic 1)

What is the correct procedure to change Ethernet switching modes?

  1. Navigate to the subordinate Fabric Interconnect in the GUI, choose quot;Set Ethernet Switching modequot;, wait for it to come back up, and repeat on the primary FI.

  2. Navigate to either Fabric Interconnect in the GUI, choose quot;Set Ethernet Switching modequot;, and wait while both FIs reboot simultaneously.

  3. Navigate to either Fabric Interconnect in the GUI and transparently update the mode to switching. Repeat on the other Fabric Interconnect.

  4. Simply start using the switching features. The Fabric Interconnect automatically reconfigures to use Ethernet Switching Mode.

Answer: B

Question No: 162 – (Topic 1)

How will the Cisco UCS Manager react when all of the FSM tasks fail?

  1. retries for 60 seconds

  2. raises faults and alarms

  3. restarts from the previous known good task

  4. sends an NOC SNMP trap email

Answer: B

Question No: 163 – (Topic 1)

A customer has Server1 working properly, configured to boot over SAN and with service profile SP1 assigned. This service profile is cloned to service profile SP2 and assigned to Server2. Before Server2 boots, which three actions needs to be performed? (Choose three.)

  1. Check the WWPN that is assigned to the vHBAs on SP2.

  2. Check the MAC address that is assigned to the vNICs on SP2.

  3. Add two vHBAs and assign them to the proper VSAN.

  4. Add the pWWN of SP2 to the zoning on the SAN switch.

  5. Change the boot target on SP2.

  6. Change the IP address of the vNICs.

Answer: A,D,E

Question No: 164 – (Topic 1)

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

What is the FCF-MACtorthis switch?

A. 54:7f:ee:98:9b:39

B. 54:7f:ee:98:9b:40

C. 54:7f:ee:98:9b:41

D. 54:7f:ee:98:9b:42

E. 54:7f:ee:98:9b:43

Answer: E

Question No: 165 – (Topic 1)

A UCS Admin is trying to launch the KVM console but it is failing to launch. All IP Pools for mgmt are configured and the CIMC has an address in UCSM. They SSH to the fabric Interconnect and run an ethanalyzer while issuing a ping from their local PC to the KVM IP address. The ping is successful but they do not see the ICMP requests and replies displayed in the capture. Here is the filter they used:

FIA(nxos)# ethanalyzer local interface mgmt display-filter icmp limit-captured-frames 0

What could be the reason pings are not seen in the capture and the KVM is failing to load?

  1. Java settings are preventing the KVM from loading

  2. There is a duplicate IP address for that CIMC address

  3. The switch upstream from the FI has the wrong vlan configured

  4. The CIMC IP pool is in the same subnet as the Fabric Interconnects mgmt 0 interface

Answer: B

Question No: 166 – (Topic 1)

Which description of a core file is true?

  1. It is generated by a system failure.

  2. It is generated by a process failure.

  3. It is generated by a component failure.

  4. It is generated by a hardware failure.

Answer: B

Question No: 167 – (Topic 1)

The Cisco UCS Manager displays FSM information for which four of these? (Choose four.)

  1. which FSM task is being executed

  2. the current state of an FSM task

  3. the status of the previous FSM task

  4. any error codes returned while processing

  5. all completed FSM tasks

  6. multiple FSM tasks that completed over multiple tries

  7. multiple FSM tasks that failed

Answer: A,B,C,D

Topic 2, Questions Set 2

Question No: 168 – (Topic 2)

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Dumps4Cert 2017 PDF and VCE

Which statement is true regarding the port channel 100 and 101 configurations between the Nexus 7010 switches?

  1. The vPC assignments on N7010-C2 are incorrectly swapped

  2. N7010-C1 is not allowing any active VLAN traffic to pass on Po100 and Po101.

  3. LACP is not configured to initiate negotiations.

  4. The vPC peer-keepalive is down between the two Nexus 7000 switches.

Answer: A Explanation:

The vPC assignments on N7010-C2 are incorrectly swapped.

The “show vpc” command will show you that the keepalives are active, and that there are active VLANs. The “show port-channel summary” command shows that LACP is enabled.

Question No: 169 – (Topic 2)

Which command can you use to determine if the member ports share the appropriate parameters in order to join a port channel?

  1. show port-channel summary

  2. show port-channel usage

  3. show port-channel compatibility-parameters

  4. show port-channel load-balance

Answer: C

Question No: 170 – (Topic 2)

Refer to the exhibit.

Dumps4Cert 2017 PDF and VCE

The server port connected to the NPV edge switch does not come online. Which action should fix the problem?

  1. Move the NP ports on the NPV edge and the F ports on the NPIV into the same VSAN 99.

  2. Move the NP ports on the NPV edge and the F ports on the NPIV in the default VSAN 1.

  3. Move all the ports into VLAN 1.

  4. Move all the ports into VSAN 99.

  5. Move all the ports into VLAN 99.

Answer: A

100% Free Download!
Download Free Demo:300-180 Demo PDF
100% Pass Guaranteed!
Download 2017 Dumps4cert 300-180 Full Exam PDF and VCE

Dumps4cert ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 Dumps4cert IT Certification PDF and VCE