Troubleshooting Cisco Data Center Infrastructure

Question No: 111 – (Topic 1)

Refer to the exhibit. Which command was executed on a Cisco UCS Fabric Interconnect in NX-OS mode to produce this output?

Dumps4Cert 2017 PDF and VCE

  1. show flogi database

  2. show npv flogi-table

  3. show flogi

  4. show npv flogi-database

  5. show fcns database

Answer: B

Question No: 112 – (Topic 1)

Which commands can you enter to see if a component in the Cisco UCS domain generated a core file?

  1. 6100-A# scope monitoring

    6100-A /monitoring # scope sysdebug 6100-A /monitoring/sysdebug # show cores

    Core Files: Name Fabric ID

    —– —–

  2. 6100-A# scope sysdebug

    6100-A /sysdebug # scope monitoring 6100-A /sysdebug/monitoring # show cores

    Core Files: Name Fabric ID

    —– —–

  3. 6100-A# scope system

    6100-A /system # scope monitoring 6100-A /system/monitoring # show cores

    Core Files: Name Fabric ID

    —– —–

  4. 6100-A# scope cores 6100-A /cores # show cores

    Core Files: Name Fabric ID

    —– —–

  5. 6100-A# scope logging

6100-A /logging # scope monitoring 6100-A /logging/monitoring # show cores

Core Files: Name Fabric ID

—– —–

Answer: A

Question No: 113 – (Topic 1)

Which two options are causes for failure of a Cisco C-Series server that is configured to boot from SAN? (Choose two.)

  1. The boot LUN ID is not 0.

  2. The ISCSI target is only available via one via one path through the network.

  3. C-Series does not support boot from SAN.

  4. The KVM dongle is attached to the front of the server with a USB stick installed.

  5. Under the FCoE properties on the vNIC adapter, the FCoE VLAN ID is set to 10.

  6. The boot table for fc0 has not been configured.

Answer: D,F

Question No: 114 – (Topic 1)

When you configure the settings for the core file exporter via UCS Manager, which field is

required to configure a destination for the core files?

  1. Admin State

  2. Description

  3. Port

  4. Hostname

  5. Path

Answer: D

Question No: 115 – (Topic 1)

Which power policy should be chosen to maximize the performance of a Cisco UCS system with four PSUs and eight blades?

  1. non-redundant

  2. N 1

  3. grid

  4. performance

Answer: C

Question No: 116 – (Topic 1)

Which two actions do you need to take to configure jumbo frames on UCS Manager? (Choose two.)

  1. Choose QoS Policy Jumbo, choose the LAN tab, and set the MTU value to 9000.

  2. Choose QoS System Class, choose the LAN tab, and set the MTU value to 9000.

  3. Choose LAN Uplinks Manager, choose the LAN tab, and set the MTU value to the uplinks VLANs to 9000.

  4. Choose the vNIC, and on the Server Profile set the MTU value to 9000.

  5. On the Admin tab, under Global Policy, enable Jumbo MTU Bytes.

  6. Go the fabric interconnect on the Equipment tab, right-click the port, and set the MTU value to 9000.

Answer: B,D

Question No: 117 – (Topic 1)

When should an operating system driver be installed or updated?

  1. during a Cisco UCS firmware update

  2. during an operating system update

  3. after reviewing the Cisco UCS B-Series Hardware and Software Interoperability Matrix and reacting accordingly

  4. when you connect the new storage system

Answer: C

Question No: 118 – (Topic 1)

Refer to the exhibit. When this configuration is entered on a fabric interconnect, which traffic is added as a source for a monitoring session?

Dumps4Cert 2017 PDF and VCE

  1. the ingress traffic on uplink port 1 on slot 3

  2. the ingress traffic on uplink port 3 on slot 1

  3. the egress traffic on uplink port 1 on slot 3

  4. the egress traffic on uplink port 3 on slot 1

Answer: D

Question No: 119 – (Topic 1)

You have blade servers that run VMware ESXi. Which two tasks do you perform to ensure that all of the components in the Cisco UCS environment use jumbo frames? (Choose two.)

  1. Use a QoS policy for the jumbo frames.

  2. Configure the MTU on the vSwitch.

  3. Configure the fabric interconnect to support 9500-byte frames.

  4. Configure the MTU on the vNIC.

  5. Configure a QoS policy on the vSwitch.

Answer: A,B

Question No: 120 – (Topic 1)

A customer starts an Auto Install upgrade process. During the process, the customer selects the wrong firmware version. Which action rolls back to the previous firmware version as quickly as possible?

  1. Cancel the process by using the Cisco UCS Manager.

  2. Wait for the upgrade to complete, and then roll back the configuration.

  3. Wait for the upgrade to complete, and then downgrade.

  4. Cancel the process by using the CLI.

Answer: C

100% Free Download!
Download Free Demo:300-180 Demo PDF
100% Pass Guaranteed!
Download 2017 Dumps4cert 300-180 Full Exam PDF and VCE

Dumps4cert ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 Dumps4cert IT Certification PDF and VCE